Shaba River Bridge event follow-up
At Shaba River Bridge in China, an X-7 abnormal-data event was reported to staff by mobile notification. A site check identified accidental contact with the device during construction; staff photographed the finding, archived the record and closed the alarm.
Shaba River Bridge · Yaxi Expressway · Sichuan, China

- Site photograph
- Asset and location
- Shaba River Bridge, Yaxi Expressway, Sichuan, China
- Monitoring point
- X-7 device at an upper bridge-pier location, as described in the company narrative
- Event route
- Abnormal data, then staff mobile notification, then site check
- Site finding
- Accidental contact with X-7 during construction
- Handling
- Photograph taken, record archived and alarm closed by staff
- Evidence basis
- Company narrative, mobile event record and site photograph

- Handling status
- Recorded measurements
From an event to a site explanation.
Detect
The company narrative describes abnormal data from the X-7 device at an upper bridge-pier location.
Review
A mobile notification reaches staff, who review the readings and device details.
Check on site
Staff check the site, identify accidental device contact during construction and photograph the finding.
Record the conclusion
Staff archive the finding and close the alarm, keeping the photograph and handling entry with the event.
Follow a recorded event.
Shaba River Bridge: the sensor record and the staff finding, kept together.
Guided view of a saved Chinese project record, assembled from its original screen and photograph.
Review the event
The record identifies a bridge-pier device and reports an abnormal event.
Check on site
Staff recorded accidental device contact during construction and attached a photograph.
Keep the conclusion
The saved record includes a handling entry and processed status.
X-7 · Sichuan, China. The source does not establish a response-time measure.
Project evidence & scope
This record documents a sensor event followed by staff investigation and closure. The cause was established through a site check, not automatic damage diagnosis. It does not demonstrate a bridge failure or a confirmed vessel impact.
The narrative and screenshot contain different event and handling timestamps. A precise event time and response duration are not stated here because their relationship has not been clarified.
Source: Fullstack Intelligence’s Chinese X-7 application brochure, page 25. This English account is a summary of company project materials; the original screenshot retains its Chinese annotations. Reviewed October 2026.
View full original project recordDiscuss the task at your site.
Share the asset, country and event you want to record. Use this X-7 project as a starting point for a site-specific evaluation.